Skip to main content
Erschienen in: International Orthopaedics 3/2015

01.03.2015 | Original Paper

Pinless navigation in total knee arthroplasty: Navigation reduced by the maximum?

verfasst von: Günther Maderbacher, Jens Schaumburger, Armin Keshmiri, Magdalena Barthel, Hans-Robert Springorum, Benjamin Craiovan, Joachim Grifka, Clemens Baier

Erschienen in: International Orthopaedics | Ausgabe 3/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Restoring a neutral mechanical axis in total knee arthroplasty (TKA) (within ±3° of varus/valgus) is associated with superior functional outcome and reduced early implant failure. Using conventional alignment jigs results in malalignment in >20 % of cases. In this study, we investigated the reduction of outliers within the threshold of ±3° of leg alignment using a “pinless” navigation system in comparison with conventional alignment jigs investigated.

Methods

In this randomised prospective study, 80 patients were randomly assigned/allocated to the pinless or conventional control group. After surgery, the two groups were compared regarding outliers > ±3° by means of hip–knee–ankle angle (HKA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal femoral angle (mLDFA) and duration of surgery. Student’s unpaired t test was used for quantitative variables, Fisher’s exact test compared groups (pinless vs. control) and a two-sided p value of ≤0.05 was considered statistically significant.

Results

In the pinless group, outliers regarding HKA and mLDFA > ±3° was significantly reduced (p = 0.025 and p = 0.002 respectively). In the pinless group, the surgery duration was significantly longer (75.6 vs. 64.5 minutes, p < 0.001).

Conclusion

Pinless navigation is effective in reducing outliers > ±3° regarding HKA without risking pin-related complications, such as fractures, infections or breaking screws. However, not all tools for conventional navigation in TKA, such as real-time measurements of the tibiofemoral axis and gap balancing, are available.
Literatur
1.
Zurück zum Zitat Jacobs CA, Christensen CP, Karthikeyan T (2014) Patient and intraoperative factors influencing satisfaction Two to five years after primary total knee arthroplasty. J Arthroplasty. doi:10.1016/j.arth.2014.03.022 Jacobs CA, Christensen CP, Karthikeyan T (2014) Patient and intraoperative factors influencing satisfaction Two to five years after primary total knee arthroplasty. J Arthroplasty. doi:10.​1016/​j.​arth.​2014.​03.​022
2.
Zurück zum Zitat Fisher DA, Dierckman B, Watts MR, Davis K (2007) Looks good but feels bad: factors that contribute to poor results after total knee arthroplasty. J Arthroplasty 22:39–42CrossRefPubMed Fisher DA, Dierckman B, Watts MR, Davis K (2007) Looks good but feels bad: factors that contribute to poor results after total knee arthroplasty. J Arthroplasty 22:39–42CrossRefPubMed
3.
Zurück zum Zitat Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed
4.
Zurück zum Zitat Huang NF, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF (2012) Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplast 27(9):1737–1741CrossRef Huang NF, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF (2012) Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplast 27(9):1737–1741CrossRef
5.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
6.
Zurück zum Zitat Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty 24:39–43CrossRefPubMed Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty 24:39–43CrossRefPubMed
7.
Zurück zum Zitat Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50CrossRefPubMed Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50CrossRefPubMed
8.
Zurück zum Zitat Gøthesen O, Espehaug B, Havelin LI, Petursson G, Hallan G, Strøm E, Dyrhovden G, Furnes O (2014) Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial. Bone Joint J 96:609–618CrossRefPubMed Gøthesen O, Espehaug B, Havelin LI, Petursson G, Hallan G, Strøm E, Dyrhovden G, Furnes O (2014) Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial. Bone Joint J 96:609–618CrossRefPubMed
9.
Zurück zum Zitat Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22:1097–1106CrossRefPubMed Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22:1097–1106CrossRefPubMed
10.
Zurück zum Zitat Hasegawa M, Yoshida K, Wakabayashi H, Sudo A (2013) Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system. Int Orthop 37(1):27–30CrossRefPubMedCentralPubMed Hasegawa M, Yoshida K, Wakabayashi H, Sudo A (2013) Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system. Int Orthop 37(1):27–30CrossRefPubMedCentralPubMed
11.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570CrossRefPubMedCentralPubMed Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570CrossRefPubMedCentralPubMed
12.
13.
Zurück zum Zitat Maculé-Beneyto F, Hernández-Vaquero D, Segur-Vilalta JM, Colomina-Rodríguez R, Hinarejos-Gomez P, García-Forcada I, Seral Garcia B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30(6):536–540CrossRefPubMedCentralPubMed Maculé-Beneyto F, Hernández-Vaquero D, Segur-Vilalta JM, Colomina-Rodríguez R, Hinarejos-Gomez P, García-Forcada I, Seral Garcia B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30(6):536–540CrossRefPubMedCentralPubMed
14.
Zurück zum Zitat Seon JK, Park SJ, Lee KB, Li G, Kozanek M, Song EK (2009) Functional comparison of total knee arthroplasty performed with and without a navigation system. Int Orthop 33(4):987–990CrossRefPubMedCentralPubMed Seon JK, Park SJ, Lee KB, Li G, Kozanek M, Song EK (2009) Functional comparison of total knee arthroplasty performed with and without a navigation system. Int Orthop 33(4):987–990CrossRefPubMedCentralPubMed
15.
Zurück zum Zitat Graydon AJ, Malak S, Anderson IA, Pitto RP (2009) Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty. Int Orthop 33(4):975–979CrossRefPubMedCentralPubMed Graydon AJ, Malak S, Anderson IA, Pitto RP (2009) Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty. Int Orthop 33(4):975–979CrossRefPubMedCentralPubMed
16.
Zurück zum Zitat Beldame J, Boisrenoult P, Beaufils P (2010) Pin track induced fractures around computer-assisted TKA. Orthop Traumatol Surg Res 96:249–255CrossRefPubMed Beldame J, Boisrenoult P, Beaufils P (2010) Pin track induced fractures around computer-assisted TKA. Orthop Traumatol Surg Res 96:249–255CrossRefPubMed
17.
Zurück zum Zitat Bonutti P, Dethmers D, Stiehl JB (2008) Case report: femoral shaft fracture resulting from femoral tracker placement in navigated TKA. Clin Orthop Relat Res 466:1499–1502CrossRefPubMedCentralPubMed Bonutti P, Dethmers D, Stiehl JB (2008) Case report: femoral shaft fracture resulting from femoral tracker placement in navigated TKA. Clin Orthop Relat Res 466:1499–1502CrossRefPubMedCentralPubMed
18.
Zurück zum Zitat Baier C, Maderbacher G, Springorum HR, Zeman F, Fitz W, Schaumburger J, Grifka J, Beckmann J (2014) No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:1819–1826CrossRefPubMed Baier C, Maderbacher G, Springorum HR, Zeman F, Fitz W, Schaumburger J, Grifka J, Beckmann J (2014) No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:1819–1826CrossRefPubMed
20.
Zurück zum Zitat Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219CrossRefPubMed Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219CrossRefPubMed
21.
Zurück zum Zitat Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130:1487–1491CrossRefPubMed Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130:1487–1491CrossRefPubMed
22.
Zurück zum Zitat Chen JY, Chin PL, Tay DK, Chia SL, Lo NN, Yeo SJ (2014) Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:1827–1832CrossRefPubMed Chen JY, Chin PL, Tay DK, Chia SL, Lo NN, Yeo SJ (2014) Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:1827–1832CrossRefPubMed
23.
Zurück zum Zitat Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331:102–106CrossRefPubMed Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331:102–106CrossRefPubMed
24.
Zurück zum Zitat Radtke S, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130:451–457CrossRefPubMed Radtke S, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130:451–457CrossRefPubMed
Metadaten
Titel
Pinless navigation in total knee arthroplasty: Navigation reduced by the maximum?
verfasst von
Günther Maderbacher
Jens Schaumburger
Armin Keshmiri
Magdalena Barthel
Hans-Robert Springorum
Benjamin Craiovan
Joachim Grifka
Clemens Baier
Publikationsdatum
01.03.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 3/2015
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2529-1

Weitere Artikel der Ausgabe 3/2015

International Orthopaedics 3/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.